inverter for railway by Enertech UPS inverter for railway by Enertech UPS
Inverter Manufacturer Company
  inverter for railway by Enertech UPS
UPS supplier pune

w
Product Range > Inverter

 

inverter for railway by Enertech UPS
   

Specifications for Railway Inverter

SPECIFICATION FOR 2.5 KVA, 110 VDC/230 AC INVERTER


  TECHNICAL REQUIREMENTS
1.
Input Voltage Min/Nom/Max.
:
90 V/110V/140V with 15% ripple
2.
Output Voltage
:
230 V AC +/-5%, 50 Hz for input voltage range of 90 to 140 V DC from no load to full load.
3.
Rated capacity
:
2.5 KVA at 90 V DC
4.
Continuous KVA Rating
:
2.5 KVA
5.
Wave form
:
Sinusoidal/PWM, THD not exceeding 3%.
6.
Cooling
:
Natural air cooled
7.
Efficiency
:
Shall not be less than 85% at full load
8.
Protection
:
- Input MCBs and fuses
- Polarity reversal at input side.
- Frequency beyond 50 +/- 3%
- Voltage surge supressor at input
- Over voltage at the input and output
- Over current protection
- Short circuit at output
- Earth protection
9.
CONSTRUCTIONAL REQUIREMENTS
:
The enclosure shall be such as to prevent ingress of brake block shoe dust liable to get attracted by the magnetic effect of the equipment. The enclosure shall meet the requirements of IP-65 protection level of IS:2147 (Latest edition). All the metal parts shall be protected from rust and corrosion. Sheet thickness will not be less than 1.6 mm.
10.
OVERALL DIMENSION
:
W = 500 mm, L = 450, H = 375 mm
as per drg. No. SKED 055 alt. 'a'.