Enertech Enertech® UPS Pvt. Ltd.
Go
FAQs Contact Us
 
   
 
 
 
  Send an Enquiry
Rating: 1 KVA - 100 KVA
Features of Lift UPS System :
  Environment Friendly   High Reliability   Extremely Flexible
  Absolutely noiseless compare to Generator   Low Operating Cost than Diesel Generator   Instant change over

Specifications of Lift UPS System :
Technology Intelligent Inverter, USING IGBT Technology
Latest Design Microcomputer-Chip based
Switching Frequency High Frequency Design ensures :
  Low Switching Losses   0P0u rity of Sine-Wave
  Ultra-fast Transient Response   Very Low Noise
Wide Input Range 350 V - 475 V AC (Three phase), 45 – 60 Hz
Accurate Output
  380 V AC ± 1.0 % (Three Phase) on Inverter Mode   350 V - 475 V AC (Three phase) on Mains Mode
  50 Hz ± 0.1% (Crystal Controlled)    
Rating 5 KVA, 6 KVA, 8KVA, 10 KVA upto 100 KVA
Output Power Factor 0.8 lagging to unity
Transient Response For 100% step load change output stays within ± 5% and recovers within ½ cycle
Metering On-board Programmable LED Panel Meter to display following parameters :
  Output Voltage   Input Voltage   Battery Voltage
  Battery Current   Output Frequency   Input Frequency
  Various conditions/Parameter of UPS Power    
Wave Form Pure Sine Wave
Distortion
  Total Harmonic Distortion Less Than 2% For Linear Load.
  Total Harmonic Distortion Less Than 5% For Non-Linear Load
Overload Rating
  100 % Continuous   150 % For 30 Seconds
Operating Temperature 0 TO 50ºC. 95 % R.H. (Maximum)
Our UPS has passed Environmental – Test From Defence Laboratory of R&DE (Engineers), Dighi, Pune
Inverter Efficiency Better Than 90%
Transfer Time 1 Sec.
Genset Compatibility Ups System Is Fully Compatible To Any Type Of Genset
Protections
  Output Over-Voltage   Output Short Circuit   Battery Under – Voltage
  Output Overload. The same shall be effective only for the normal continuous operation.
  Forced Air-cooling to protect electronic other components from overheating.
Indications
  Mains/Charger On   Inverter ON   System Over-load
  Battery Under-Voltage   Output Under/Over Voltage    
Alarms
  Mains Fail (Musical Alarm)   Battery Low Warning (Musical Alarm)
Low Noise Less Than Or Equal To 45 Db (A) (Standard) At 1.0 Mtr.
By pass Arrangement Manual By Pass Switch
Battery Charger
  Charger Is Designed On Boost / Trickle (Cccv). Principle to keep batteries in top condition.
  Uses High Frequency design to ensure long battery life.

Applications of Lift UPS System :
  Elevators   Lifts   Process motors

  Send an Enquiry