Online UPS-GTX

Rating : 10KVA to 100KVA

Enertech group one of the popular online UPS manufacturers provides Online UPS to solve energy problems. With its offices in Mumbai and Pune, Enertech products range from online UPS, inverters, solar PCU and other customized products. Enertech Online UPS solutions are designed and developed using double conversion technology. These indigenously manufactured machines are known for high performance and high quality standards and are preferred all over India. Enertech is one of the online UPS suppliers who provide solutions needed to protect computers, data processing and telecommunication, medical diagnosis, for sensitive and critical processing units and so on. Being one of the premier online UPS manufacturers, we provide machines to defence and other government institutions. The company is approved under DGS&D rate contract India, which is applicable for the purchase of UPS for government institutions.

The company offers inbuilt IGBT based rectifier to provide active input power factor correction with i/p PF up to 0.99 and with less than 10% input current harmonics. Also provides continuous backup and the online UPS acts as power conditioner thereby reducing the electricity bills for the customers. These features make Enertech Group one of the most desirable Online UPS Suppliers in India.

This leading name among the online UPS manufacturers brings solutions with built-in galvanic isolation via transformers. The transformer eliminates the problems associated with common mode noise, neutral, phase reversal and earth potential drifts which can cause irrecoverable loss. We are among those Indian online UPS suppliers with the capability to offer customized power solutions as per customer requirements and site conditions.

Enertech known as the leaders of online UPS manufacturers presents Online UPS GTX Model with some of the ideal features like

  • Charger Electrical Vehicle
  • Double conversion technology is used in this model
  • A Low input current distortion level with high efficiency
  • Advanced network and mobile connectivity
  • Active/passive harmonic filter at the UPS input.
  • Have an active input power factor correction
  • Have got a built-in galvanic isolation transformer for reducing the common mode noise.
  • IGBT based design for reduced power consumption
  • Has Hot standby UPS and load sharing mode for 24x7 operation
  • Have SNMP/MODBUS connectivity
  • Rugged Design
  • Wide input voltage range
  • Suitable for places with huge variation in grid supply
  • High reliability
  • Long Life
  • Ideal for High DC

Online UPS-GTX

Rating (3PH-1PH) 5KVA-40KVA
Charger SCR Based
DC Voltage 180V DC - 360 V DC
Technology Intelligent UPS
USING IGBT Technology
Latest Design Microcomputer-Chip based PWM Technology
Switching Frequency Low Switching Losses
Purity of Sine-Wave
Ultra-fast Transient Response
Very Low Noise
Wide Input Range 360V - 470V AC (Three phase)
45 – 60 Hz
Accurate Output 230 V AC ± 1.0 % (Single Phase)
50 Hz ± 0.1% (Crystal Controlled)
Output Power Factor Duty 0.8 lagging to unity continuous
Transient Response For 100% step load change output stays within ± 5% and
recovers within 5 milliseconds for 50% step load change
output stays within +/- 3% of nominal voltage and recover
within 5 milliseconds
Metering On-board Programmable LED/LCD Panel Meter to
Display following parameters :
Output Voltage
Input Voltage
Battery Voltage
Backup %
Output Frequency
Input Frequency
Various conditions/Parameter of UPS Power
Wave Form Pure Sine Wave
Distortion(THD) Total Harmonic Distortion less than 2% for linear load.
Total Harmonic Distortion less than 5% for non-linear load
Overload Rating 100 % Continuous
125% for 5 mts
Operating Temperature 0 to 50ºC. 95 % R.H. (Maximum)
Our UPS has passed Environmental – Test From Defense
Laboratory of R&DE (Engineers), Dighi, Pune
Inverter Efficiency Better than 80 %
Transfer Time Zero
Genset Compatibility Inverter System is fully Compatible to any type of Genset
Protections Output Over-Voltage
Output Overload. The same shall be effective only for the
normal continuous operation. (above 150%)Output Short CircuitBattery Under – Voltage

Forced Air-cooling to protect electronic other components

Indications Mains/Charger ON

Inverter ON

System Over-load

Battery Under-Voltage

Output Under/Over Voltage

Alarms Mains Fail (Musical Alarm) (Auto reset)

Battery Low Warning (Musical Alarm)

Low Noise Less than or equal to 45 db (a) (standard) at 1.0 mtr. Above
Battery Charger Charger is designed on Float Boost (CCCV) Principle to
Keepbatteries in top condition.Uses High Frequency design to ensure long battery life.

Online UPS-GTX

Rating (3PH-3PH) 5KVA - 150KVA
Charger SCR Based
DC Voltage 240 VDC - 360 V DC
Technology Intelligent UPS using IGBT Technology
Latest Design Microcomputer-Chip based PWM Technology
Switching Frequency Low Switching Losses
Purity of Sine-Wave
Ultra-fast Transient Response
Very Low Noise
Wide Input Range 360V - 460V AC (Three phase)
45 – 60 Hz
Accurate Output 415 V AC ± 1.0 % (Single Phase)
50 Hz ± 0.1% (Crystal Controlled)
Output Power Factor Duty 0.8 lagging to unity continuous
Transient Response For 100% step load change output stays within ± 5% and
recovers within 5 milliseconds for 50% step load change
output stays within +/- 3% of nominal voltage and recover
within 5 milliseconds
Metering On-board Programmable LED/LCD Panel Meter to
Display following parameters :
Output Voltage
Input Voltage
Battery Voltage
Backup %
Output Frequency
Input Frequency
Various conditions/Parameter of UPS Power
Wave Form Pure Sine Wave
Distortion Total Harmonic Distortion less than 2% for linear load.
Total Harmonic Distortion less than 5% for non-linear load
Overload Rating 100 % Continuous
125% for 5 mts
Operating Temperature 0 to 50ºC. 95 % R.H. (Maximum)
Our UPS has passed Environmental – Test From Defense
Laboratory of R&DE (Engineers), Dighi, Pune
Inverter Efficiency Better than 80 %
Transfer Time Zero
Genset Compatibility Inverter System is fully Compatible to any type of Genset
Protections Output Over-Voltage
Output Overload. The same shall be effective only for the
normal continuous operation. (above 150%)Output Short CircuitBattery Under – VoltageForced Air-cooling to protect electronic other components
Indications Mains/Charger ON

Inverter ON

System Over-load

Battery Under-Voltage

Output Under/Over Voltage

Alarms Mains Fail (Musical Alarm) (Auto reset)

Battery Low Warning (Musical Alarm)

Low Noise Less than or equal to 45 db (a) (standard) at 1.0 mtr. Above
Battery Charger Charger is designed on Float Boost (CCCV) Principle to
Keepbatteries in top condition.Uses High Frequency design to ensure long battery life.
  • ENERTECH - UPS CATALOGUE
  • Quick Quote