Solar Hybrid PCU - 1Phase

Model : SunMagic
Rating : 1KVA to 15KVA

SUN MAGIC is a state of art PCU product from ENERTECH product basket with Global standards. This unit will give operational flexibility to its customers to enjoy the benefits of advanced monitoring and control features.

Grid power in Indian subcontinent frequently suffers from voltage &/or frequency variations , Grid outages, voltage sag/ surges which inhibits users from enjoying benefits of solar grid tied systems.
SUN MAGIC series has evolved to overcome the limitations and give maximum possible yield to its users using DSP based advance control and monitoring features.

SUN MAGIC product range aims to cater roof top requirement for commercial, Individual and utility scale solar plant requirements with 3Phase grid export + battery backup feature.

SUN MAGIC range of products are ideal for projects ranging from 1KWp to 15KWp array installations-1Phase applications. SUN MAGIC product, packaged with optional data monitoring software, GSM based wireless monitoring provides perfect solution for power plant management large scale.

  • Bidirectional solar PCU
  • Hybrid inverter (Solar/ Grid/BATT)
  • Vector Modulated Inverter Control
  • Multiple DSP control operation
  • Range 1KVA to 15KVA
  • Battery Less operation compatible
  • Paralleling Compatibility
  • MPPT Based Solar Charger -2 modes of operations
  • Higher Capacity PV connection option available
  • Multi Mode function: SGB/ SBG/GFM (selectable)
  • SBG Modes with Buffer level selection facility 25/50/75
  • GFM FEED mode feeds power to grid when grid available, feeds power to load when grid fails.
  • GFM levels are selectable 0/25/50/75/100
  • Unity power Factor for grid charging
  • Adjustable Grid Charging Current:
  • Vthd <3%
  • Changeover time less than 20ms
  • 20 X 4 LCD with backlight & Tactile Kay Pad Interface
  • Detailed Metering : Solar KW , Solar KWH,
  • Fault logs : 6 recent faults
  • Auto fault reset for non critical faults
  • Optional Input : Pyranometer , Wind speed, Battery
  • Generator compatible
  • Communication Port: RS232
  • GSM Based Remote Monitoring option
  • Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 1 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 1 KWP
    Max. Open Circuit PV Volts (Voc) 150V
    MPPT Voltage Range 65 –120V
    Minimum PV Voltage 65V
    Max I/P Amps per channel 21A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 48
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 800WP
    Output AMP 3.5
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Indication

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters Load Status

    Load on Batt

    Grid CHRG

    Grid Sharing

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 2 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 2 KWP
    Max. Open Circuit PV Volts (Voc) 150V
    MPPT Voltage Range 65 –120V
    Minimum PV Voltage 65V
    Max I/P Amps per channel 41A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 48
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 1600WP
    Output AMP 7
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Indication

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters INPUT GRP

     

    Voltage

    Current

    Frequency

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 3 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 3 KWP
    Max. Open Circuit PV Volts (Voc) 250V
    MPPT Voltage Range 130 –200V
    Minimum PV Voltage 130V
    Max I/P Amps per channel 31A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 96
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 2400WP
    Output AMP 10.5
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 94%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility    Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Indications

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters INPUT GRP

     

    Voltage

    Current

     

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 5 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 5KWP
    Max. Open Circuit PV Volts (Voc) 250V
    MPPT Voltage Range 130 –200V
    Minimum PV Voltage 130V
    Max I/P Amps per channel 52A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 96
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 4000WP
    Output AMP 17
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Indications

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters

    O/P GRP

    Voltage

    Current

    Frequency

     

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 6 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 6 KWP
    Max. Open Circuit PV Volts (Voc) 250V
    MPPT Voltage Range 130 –200V
    Minimum PV Voltage 130V
    Max I/P Amps per channel 62A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 96
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 4800WP
    Output AMP 21
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 94%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Indications

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters Solar GRP

     

    PV Vol,Curr

    PV Power

    PV Energy

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 8 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 8 KWP
    Max. Open Circuit PV Volts (Voc) 300V
    MPPT Voltage Range 165–250V
    Minimum PV Voltage 165V
    Max I/P Amps per channel 66A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 120
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 800WP
    Output AMP 3.5
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Indication

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters Batt GRP

    Voltage

    Status

    Current CH

    Current DISC

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 10 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 10 KWP
    Max. Open Circuit PV Volts (Voc) 300V
    MPPT Voltage Range 165–250V
    Minimum PV Voltage 165V
    Max I/P Amps per channel 83A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 120
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 800WP
    Output AMP 35
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Indication

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters Dash board

    Input KW

    Output KW

    Solar KW

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 12.5 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 12.5 KWP
    Max. Open Circuit PV Volts (Voc) 300V
    MPPT Voltage Range 165–250V
    Minimum PV Voltage 165V
    Max I/P Amps per channel 104A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 120
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 800WP
    Output AMP 3.5
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Indications

    LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
    LCD Display Parameters Faults

    Recent 6

    fault since

    last reset

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2

    Grid Charger

    Grid Voltage Sync Range 170V to 260V (±5V)
    Grid Frequency Sync Range 50Hz ± 6%
    Charger Peak Efficiency Higher than 90%
    Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
    Max Batt Amp (Charging) 5A to 20A selectable
    Self Consumption Lower than 4%
    Recommended DG/GRID Capacity Double of Inverter Capacity

    Solar Charge Controller

    Charge Controller Type MPPT
    Charger Topology BUCK
    MAX PV Connection Capacity 15 KWP
    No of MPPT Channels 1
    Per Channel PV Capacity (Nominal/ Peak) 15 KWP
    Max. Open Circuit PV Volts (Voc) 300V
    MPPT Voltage Range 165–250V
    Minimum PV Voltage 165V
    Max I/P Amps per channel 125A
    Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
    Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
    Peak Charging Efficiency Higher than 94% Upto 98%

    Inverter

    Nominal Battery Voltage VDC 120
    No of Phases/Connection Type 1Ph , 3 Wire- LNE
    Nominal Output Voltage 230V AC ±2%
    Output Frequency 50Hz ± 0.5%
    Continues Output Power 800WP
    Output AMP 3.5
    Voltage Regulation(Stand Alone) ±2%
    Frequency Regulation(Stand Alone) ±0.5Hz
    THD THD less than 4%
    OUTPUT Waveform Pure Sine Wave
    Galvanic Isolation In built Isolation Transformer at Inverter Output
    Output Power Factor 0.8lagging
    Peak Efficiency (Full Load) Higher than 75%
    Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
    DG Compatibility Available
    Auto Bypass feature Available
    Grid Export Mode Available, Enable/Disable Options available
    Anti Islanding Function Available, In Compliance with IEC 62116
    Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

    Configuration

    Modes Available 3:Hybrid,Grid Export ,Stand Alone
    Battery Buffer Setting Selectable from 25%,50%,75%
    MPPT Modes 2
    • Sunmagic New

    Quick Quote

    TOP
    Get A Free Quote

    Contact us for free quote