Solar Hybrid PCU 3Phase

Model : SunMagic+
Rating : 10KVA to 100KVA

SUN MAGIC+ is a state of art PCU product from ENERTECH product basket with Global standards. This unit will give operational flexibility to its customers to enjoy the benefits of advanced monitoring and control features.

Grid power in Indian subcontinent frequently suffers from voltage &/or frequency variations , Grid outages, voltage sag/ surges which inhibits users from enjoying benefits of solar grid tied systems.

SUN MAGIC+ series has evolved to overcome the limitations and give maximum possible yield to its users using DSP based advance control and monitoring features.

SUN MAGIC+ product range aims to cater roof top requirement for commercial, Individual and utility scale solar plant requirements with 3Phase grid export + battery backup feature.

SUN MAGIC+ range of products are ideal for projects ranging from 10KWp to 100KWp array installations-3Phase applications. SUN MAGIC+ product, packaged with optional data monitoring software, GSM based wireless monitoring provides perfect solution for power plant management large scale.

  • Bidirectional solar PCU
  • Hybrid inverter (Solar/ Grid/BATT)
  • Vector Modulated Inverter Control
  • Multiple DSP control operation
  • Range 10KW to 100KW
  • Battery Less operation compatible
  • Paralleling Compatibility
  • MPPT Based Solar Charger -2 modes of operations
  • Higher Capacity PV connection option available
  • Multi Mode function: SGB/ SBG/GFM (selectable)
  • SBG Modes with Buffer level selection facility 25/50/75
  • GFM FEED mode feeds power to grid when grid available, feeds power to load when grid fails.
  • GFM levels are selectable 0/25/50/75/100
  • Unity power Factor for grid charging
  • Adjustable Grid Charging Current:
  • Vthd <3%
  • Changeover time less than 20ms
  • 40 X 4 LCD with backlight & Tactile Kay Pad Interface
  • Detailed Metering : Solar KW , Solar KWH,
  • Fault logs : 9 recent faults
  • Auto fault reset for non critical faults
  • Optional Input : Pyranometer , Wind speed, Battery Temperature, Heat sink Temperature
  • Advanced Battery Management Feature
  • Temperature Compensated Charging
  • Generator compatible
  • Communication Port: RS232
  • GSM Based Remote Monitoring option

Grid Charger

Grid Voltage Sync Range 330V to 450V(±5V)
Grid Frequency Sync Range 50Hz ± 6%
Charger Peak Efficiency Higher than 90%
Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
Max Batt Amp (Charging) 5A to 200A subjected to battery capacity and inverter rating
Self Consumption Lower than 4%
Recommended DG/GRID Capacity Double of Inverter Capacity

Solar Charge Controller

Charge Controller Type MPPT
Charger Topology BUCK
MAX PV Connection Capacity 10KWP to 20KWP
No of MPPT Channels 1
Per Channel PV Capacity (Nominal/ Peak) 10KWP to 20KWP
Max. Open Circuit PV Volts (Voc) 300V to 500V
MPPT Voltage Range 165V to 400V
Minimum PV Voltage 165V to 290V
Max I/P Amps per channel 83A
Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
Peak Charging Efficiency Higher than 94% Upto 98%

Inverter

Controller DSP
Switching Element IGBT
Nominal Battery Voltage VDC 120 to 240
No of Phases/Connection Type 3Ph , 4 Wire- RYBN
Nominal Output Voltage 400V AC ±2%,
Output Frequency 50Hz ± 0.5%
Continues Output Power 8KWP to 16KWP
Output AMP 11 to 23
Voltage Regulation(Stand Alone) ±2%
Frequency Regulation(Stand Alone) ±0.5Hz
THD V THD <3% | I THD <10%
OUTPUT Waveform Pure Sine Wave
Galvanic Isolation In built Isolation Transformer at Inverter Output
Output Power Factor 1.0 to 0.6 Lagging
Peak Efficiency (Full Load) Upto 90%%
Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
DG Compatibility 30.00%
Auto Bypass feature Available
Grid Export Mode Available, Enable/Disable Options available
Anti Islanding Function Available, In Compliance with IEC 62116
Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

Indication

LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
LCD Display Parameters Date, Time, Total Up Time, Total Down Time, Current Up Time, Current Down Time, Current Status
INPUT GRP Voltages Currents Frequency Power W Power VA Import KWH Export KWH
DG GRP Power W Power VA KWH Run Hr
Alarm Audible For Fault And Warnings

Configuration

Modes Available 3:Hybrid,Grid Export ,Stand Alone
Battery Buffer Setting Selectable from 25%,50%,75%
MPPT Modes 2

Protection

PV Reverse Polarity Indication , Reverse Polarity Indication , Surge Protection
Grid Over/ under Voltage, Over/ Under Frequency, Surge Protection
Battery Reverse Polarity Over/ Under Voltage, Over Temp, Over Charge
Load Overloads, Short circuit
Circuit Breakers Grid Input MCB/MCCB, Battery Input MCB/MCCB, PV Input MCB/MCCB, Load Rotary Switch
Temperature Inverter Over Temperature

Enclosure

Degree of Protection IP 20 Compatible to IEC 60529:2001-02- As per MNRE Requirement
Cooling Temperature Dependent Forced Cooling
Noise <50dB
Color Siemens Grey/Blue
Termination Bottom

Environmental

Temperature Range (Operating) 0 to 50°C
Temperature Range (Storage) -10 to 50°C
Altitude (max) 1000 m
Humidity 0-95% NON Condensing
Compatible IEC standards IEC- 60068-2-1, IEC-60068-2-2, IEC-60068-2-14, IEC-60068-2-30- As per MNRE Requirement

Connectivity

RS-232/GSM

Grid Charger

Grid Voltage Sync Range 330V to 450V(±5V)
Grid Frequency Sync Range 50Hz ± 6%
Charger Peak Efficiency Higher than 90%
Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
Max Batt Amp (Charging) 5A to 200A subjected to battery capacity and inverter rating
Self Consumption Lower than 4%
Recommended DG/GRID Capacity Double of Inverter Capacity

Solar Charge Controller

Charge Controller Type MPPT
Charger Topology BUCK
MAX PV Connection Capacity 25KWP to 40 KWP
No of MPPT Channels 1
Per Channel PV Capacity (Nominal/ Peak) 25KWP-40KWP
Max. Open Circuit PV Volts (Voc) 500V-700V
MPPT Voltage Range 165V -400V
Minimum PV Voltage 290V to 450V
Max I/P Amps per channel 104A to 110A
Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
Peak Charging Efficiency Higher than 94% Upto 98%

Inverter

Controller DSP
Switching Element IGBT
Nominal Battery Voltage VDC 120 to 240
No of Phases/Connection Type 3Ph , 4 Wire- RYBN
Nominal Output Voltage 400V AC ±2%,
Output Frequency 50Hz ± 0.5%
Continues Output Power 8KWP to 16KWP
Output AMP 11 to 23
Voltage Regulation(Stand Alone) ±2%
Frequency Regulation(Stand Alone) ±0.5Hz
THD V THD <3% | I THD <10%
OUTPUT Waveform Pure Sine Wave
Galvanic Isolation In built Isolation Transformer at Inverter Output
Output Power Factor 1.0 to 0.6 Lagging
Peak Efficiency (Full Load) Upto 90%%
Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
DG Compatibility 30.00%
Auto Bypass feature Available
Grid Export Mode Available, Enable/Disable Options available
Anti Islanding Function Available, In Compliance with IEC 62116
Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

Indication

LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
LCD Display Parameters Date, Time, Total Up Time, Total Down Time, Current Up Time, Current Down Time, Current Status
O/P GRP Voltages Currents Frequency Power W Power VA Import KWH Export KWH
Power GRP Total I/P KW,KVA
Total O/P KW,KVA
Input PF
Output PF
Invert GRP Voltages Currents Frequency Power KW Power VA

Configuration

Modes Available 3:Hybrid,Grid Export ,Stand Alone
Battery Buffer Setting Selectable from 25%,50%,75%
MPPT Modes 2

Protection

PV Reverse Polarity Indication , Reverse Polarity Indication , Surge Protection
Grid Over/ under Voltage, Over/ Under Frequency, Surge Protection
Battery Reverse Polarity Over/ Under Voltage, Over Temp, Over Charge
Load Overloads, Short circuit
Circuit Breakers Grid Input MCB/MCCB, Battery Input MCB/MCCB, PV Input MCB/MCCB, Load Rotary Switch
Temperature Inverter Over Temperature

Enclosure

Degree of Protection IP 20 Compatible to IEC 60529:2001-02- As per MNRE Requirement
Cooling Temperature Dependent Forced Cooling
Noise
Color Siemens Grey/Blue
Termination Bottom

Environmental

Temperature Range (Operating) 0 to 50°C
Temperature Range (Storage) -10 to 50°C
Altitude (max) 1000 m
Humidity 0-95% NON Condensing
Compatible IEC standards IEC- 60068-2-1, IEC-60068-2-2, IEC-60068-2-14, IEC-60068-2-30- As per MNRE Requirement

Connectivity

RS-232/GSM

Grid Charger

Grid Voltage Sync Range 330V to 450V(±5V)
Grid Frequency Sync Range 50Hz ± 6%
Charger Peak Efficiency Higher than 90%
Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
Max Batt Amp (Charging) 5A to 200A subjected to battery capacity and inverter rating
Self Consumption Lower than 4%
Recommended DG/GRID Capacity Double of Inverter Capacity

Solar Charge Controller

Charge Controller Type MPPT
Charger Topology BUCK
MAX PV Connection Capacity 50KWP to 60 KWP
No of MPPT Channels 1
Per Channel PV Capacity (Nominal/ Peak) 50KWP to 60 KWP
Max. Open Circuit PV Volts (Voc) 700V
MPPT Voltage Range 450V -600V
Minimum PV Voltage 450V
Max I/P Amps per channel 138A to 165A
Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
Peak Charging Efficiency Higher than 94% Upto 98%

Inverter

Controller DSP
Switching Element IGBT
Nominal Battery Voltage VDC 360V
No of Phases/Connection Type 3Ph , 4 Wire- RYBN
Nominal Output Voltage 400V AC ±2%,
Output Frequency 50Hz ± 0.5%
Continues Output Power 8KWP to 16KWP
Output AMP 11 to 23
Voltage Regulation(Stand Alone) ±2%
Frequency Regulation(Stand Alone) ±0.5Hz
THD V THD <3% | I THD <10%
OUTPUT Waveform Pure Sine Wave
Galvanic Isolation In built Isolation Transformer at Inverter Output
Output Power Factor 1.0 to 0.6 Lagging
Peak Efficiency (Full Load) Upto 90%%
Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
DG Compatibility 30.00%
Auto Bypass feature Available
Grid Export Mode Available, Enable/Disable Options available
Anti Islanding Function Available, In Compliance with IEC 62116
Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

Indication

LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
LCD Display Parameters Date, Time, Total Up Time, Total Down Time, Current Up Time, Current Down Time, Current Status
Solar GRP PV Vol, Curr
PV Power
PV Energy
Panel Temp
PVRadiation
Batt GRP Voltage
Current
I/P KWH
O/P KWH
Batt Temp
Batt %

Configuration

Modes Available 3:Hybrid,Grid Export ,Stand Alone
Battery Buffer Setting Selectable from 25%,50%,75%
MPPT Modes 2

Protection

PV Reverse Polarity Indication , Reverse Polarity Indication , Surge Protection
Grid Over/ under Voltage, Over/ Under Frequency, Surge Protection
Battery Reverse Polarity Over/ Under Voltage, Over Temp, Over Charge
Load Overloads, Short circuit
Circuit Breakers Grid Input MCB/MCCB, Battery Input MCB/MCCB, PV Input MCB/MCCB, Load Rotary Switch
Temperature Inverter Over Temperature

Enclosure

Degree of Protection IP 20 Compatible to IEC 60529:2001-02- As per MNRE Requirement
Cooling Temperature Dependent Forced Cooling
Noise
Color Siemens Grey/Blue
Termination Bottom

Environmental

Temperature Range (Operating) 0 to 50°C
Temperature Range (Storage) -10 to 50°C
Altitude (max) 1000 m
Humidity 0-95% NON Condensing
Compatible IEC standards IEC- 60068-2-1, IEC-60068-2-2, IEC-60068-2-14, IEC-60068-2-30- As per MNRE Requirement

Connectivity

RS-232/GSM

Grid Charger

Grid Voltage Sync Range 330V to 450V(±5V)
Grid Frequency Sync Range 50Hz ± 6%
Charger Peak Efficiency Higher than 90%
Max Grid Import Power Capacity Double of Inveter capacity dependent on battery charging current
Max Batt Amp (Charging) 5A to 200A subjected to battery capacity and inverter rating
Self Consumption Lower than 4%
Recommended DG/GRID Capacity Double of Inverter Capacity

Solar Charge Controller

Charge Controller Type MPPT
Charger Topology BUCK
MAX PV Connection Capacity 80KWP to 100 KWP
No of MPPT Channels 1
Per Channel PV Capacity (Nominal/ Peak) 80KWP to 100 KWP
Max. Open Circuit PV Volts (Voc) 500V-700V
MPPT Voltage Range 450V -600V
Minimum PV Voltage 450V
Max I/P Amps per channel 220A to 275A
Max Battery Amps during PV charging Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH
Battery type Supported LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement
Peak Charging Efficiency Higher than 94% Upto 98%

Inverter

Controller DSP
Switching Element IGBT
Nominal Battery Voltage VDC 120 to 240
No of Phases/Connection Type 3Ph , 4 Wire- RYBN
Nominal Output Voltage 400V AC ±2%,
Output Frequency 50Hz ± 0.5%
Continues Output Power 40KWP to 48KWP
Output AMP 92 to 116
Voltage Regulation(Stand Alone) ±2%
Frequency Regulation(Stand Alone) ±0.5Hz
THD V THD <3% | I THD <10%
OUTPUT Waveform Pure Sine Wave
Galvanic Isolation In built Isolation Transformer at Inverter Output
Output Power Factor 1.0 to 0.6 Lagging
Peak Efficiency (Full Load) upto 92%%
Overload capacity 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized
DG Compatibility 30.00%
Auto Bypass feature Available
Grid Export Mode Available, Enable/Disable Options available
Anti Islanding Function Available, In Compliance with IEC 62116
Compatible IEC standards IEC -61683:1999- As per MNRE Requirement

Configuration

Modes Available 3:Hybrid,Grid Export ,Stand Alone
Battery Buffer Setting Selectable from 25%,50%,75%
MPPT Modes 2

Protection

PV Reverse Polarity Indication , Reverse Polarity Indication , Surge Protection
Grid Over/ under Voltage, Over/ Under Frequency, Surge Protection
Battery Reverse Polarity Over/ Under Voltage, Over Temp, Over Charge
Load Overloads, Short circuit
Circuit Breakers Grid Input MCB/MCCB, Battery Input MCB/MCCB, PV Input MCB/MCCB, Load Rotary Switch
Temperature Inverter Over Temperature

Indication

LED Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault
LCD Display Parameters Date, Time, Total Up Time, Total Down Time, Current Up Time, Current Down Time, Current Status
O/P GRP Voltages Currents Frequency Power W Power VA Import KWH Export KWH
Power GRP Total I/P KW,KVA
Total O/P KW,KVA
Input PF
Output PF
Invert GRP Voltages Currents Frequency Power KW Power VA

Enclosure

Degree of Protection IP 20 Compatible to IEC 60529:2001-02- As per MNRE Requirement
Cooling Temperature Dependent Forced Cooling
Noise
Color Siemens Grey/Blue
Termination Bottom

Environmental

Temperature Range (Operating) 0 to 50°C
Temperature Range (Storage) -10 to 50°C
Altitude (max) 1000 m
Humidity 0-95% NON Condensing
Compatible IEC standards IEC- 60068-2-1, IEC-60068-2-2, IEC-60068-2-14, IEC-60068-2-30- As per MNRE Requirement

Connectivity

RS-232/GSM
  • Sunmagic+ New