1.
|
Technology |
:
|
Intelligent UPS, USING IGBT
Technology |
|
2.
|
Latest Design |
:
|
Microcomputer-Chip based |
|
3.
|
Switching Frequency |
:
|
High Frequency, (Greater than 17.5 KHz.) to ensure
-
* Low Switching Lossess
* Purity of Sine-Wave
* Ultra-fast Transient
Response
* Very Low Noise |
|
4.
|
Wide Input Range |
:
|
* 350 V - 475 V AC (Three phase) OR
*160 V - 270 V AC (Single phase)
* 45 - 60 Hz |
|
5.
|
Accurate Output |
:
|
*415 v AC 1.0% (Three Phase) OR
* 230 V AC + 1.0 % (Single phase)
50 Hz + 0.1 % (Crystal Controlled)
|
|
6.
|
Ratings |
:
|
1.0 - 60.0 KVA |
|
7.
|
Output Power Factor |
:
|
0.8 lagging to unity |
|
8.
|
Transient Response |
:
|
* For 100 % step load change output stays within
+ 5% and recovers within 1/2 cycle |
|
9.
|
Metering |
:
|
On-board Programmable LCD Panel meter to display
following parameters :
* Output Voltage *
Input Voltage
* Battery Voltage *
Battery Current
* Output Frequency *
Input Frequency
* Various conditions/Parameter of UPS Power
OR
Digital Meter showing Input/Output
Volts through selection. |
|
10
|
Wave Form |
:
|
Pure Sine Wave |
|
11.
|
Distortion |
:
|
* Total Harmonic Distortion less than 2% for linear
load
* Total Harmonic Distortion less than 5% for non-linear load
|
|
12.
|
Overload Rating |
:
|
100 % Continuous 150% for 30 seconds |
|
13.
|
Operating Temperature |
:
|
0 to 50o C, 95% R.H. (Maximum)
Our UPS has passess Environmental - Tests From Defence Laboratory
of
R&DE (Engineers), Dighi, Pune. |
|
14.
|
Inverter Efficiency |
:
|
* Better than 90% |
|
15
|
Transfer Time |
:
|
Zero |
|
16.
|
Genset Compatibility |
:
|
* UPS System is fully Compatible to any type of
Genset |
|
17.
|
Protections |
:
|
* Output Over-Voltage
* Output Overload. The same shall be effective only for the
normal continuous operations.
* Output Short Circuit
* Battery Under-Voltage
* Forced Air-cooling to protect electronic other components
from overheating. |
|
18.
|
Indications |
:
|
* Mains/Charger ON
* Inverter ON
* System Over-load
* Battery Under-Voltage
* Output Under/Over Voltage |
|
19.
|
Alarms |
:
|
* Mains Fail (Musical Alarm)
* Battery Low Warning (Musical Alarm) |
|
20.
|
Low Noise |
:
|
Less than or Equal to 45 dB (A) (Standard)
at 1.0mtr. |
|
21.
|
Bypass Arrangement |
:
|
* In-built Solid-State Static Switch provided
(For UPS of 7.5 KVA and above ratings)
* Manual Changeover Switch provided (For 1.0 to 6.0 KVA
UPS Systems). |
|
22.
|
Battery Charger |
:
|
* Charger is designed on Boost/Trickle (CCCV)
principle to keep batteries in top condition.
* Uses High Frequency design to ensure long battery life. |
|
23.
|
Useful Options |
:
|
a) Servo-Voltage Stabiliser for use in bypass
mode
b) Synchronised/Asynchronised Inverter Configuration
c) Critical / Non-Critical Redundant UPS
d) Dual-Redundant (Hot Standby/Load Sharing) UPS Configuration
e) Scott - Connected Transformer for Single phasing of Input
AC Mains And steppingdown the Mains
Voltage from 415 V to 270 V AC in bypass
mode (Recommended for 10.0 KVA UPS and above with 3- phase
Input)
f) Computer Interface (RS-232) for Automatic Unattended Shutdown
of file- server & Monitoring of
Battery Status. Options available for Novell- LAN/NT-WINDOWS/SCO-UNIX/LINUX.
g) Remote Control indications & Alarms Panel
to control the UPS functions from
a distance.
|