SUN MAGIC is a state of art PCU product from ENERTECH product basket with Global standards. This unit will give operational flexibility to its customers to enjoy the benefits of advanced monitoring and control features. Enertech is solar inverter manufacturer and solar inverter suppliers. We are leading of solar PCU manufacturers started range from 1KW to 150KW.
Grid power in Indian subcontinent frequently suffers from voltage &/or frequency variations , Grid outages, voltage sag/ surges which inhibits users from enjoying benefits of solar grid tied systems.
SUN MAGIC series has evolved to overcome the limitations and give maximum possible yield to its users using DSP based advanced control and monitoring features.
SUN MAGIC product range aims to cater roof top requirement for commercial, Individual and utility scale solar plant requirements with 3Phase grid export + battery backup feature.
SUN MAGIC range of products are ideal for projects ranging from 1KWp to 15KWp array installations-1Phase applications. SUN MAGIC product, packaged with optional data monitoring software, GSM based wireless monitoring provides the perfect solution for power plant management large scale.
Que - How should I decide rating of Inverter ?
Ans - Rating of inverter is decided by using load details.
Que - How should I decide rating of battery ?
Ans - Rating of battery is depend on how many hours of backup you require.
Que - How should I decide rating of solar panel ?
Ans - Rating of solar panel is depends upon how much kw of generation you require to run your load to charge battery.
Que - Which load should I put on solar ?
Ans - Residential, commercial, industrial load, Lighting load
Que - Why do system fails ?
Ans - System fails due to improper protection and improper site related issues such as protection, earthings, lightning arrestor, due to horrible dust and ventilation.
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 2 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 2 KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 150V | |||||||||||
MPPT Voltage Range | 65 –120V | |||||||||||
Minimum PV Voltage | 65V | |||||||||||
Max I/P Amps per channel | 41A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 48 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 1600WP | |||||||||||
Output AMP | 7 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 75% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters | INPUT GRP
Voltage Current Frequency |
Modes Available | 5: SBG, SGB, GSB, GFM, INV |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 3 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 3 KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 250V | |||||||||||
MPPT Voltage Range | 130 –200V | |||||||||||
Minimum PV Voltage | 130V | |||||||||||
Max I/P Amps per channel | 31A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 96 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 2400WP | |||||||||||
Output AMP | 10.5 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 94% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
Modes Available | 3:Hybrid,Grid Export ,Stand Alone |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters | INPUT GRP
Voltage Current
|
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 5 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 5KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 250V | |||||||||||
MPPT Voltage Range | 130 –200V | |||||||||||
Minimum PV Voltage | 130V | |||||||||||
Max I/P Amps per channel | 52A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 96 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 4000WP | |||||||||||
Output AMP | 17 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 75% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters |
O/P GRP Voltage Current Frequency
|
Modes Available | 3:Hybrid,Grid Export ,Stand Alone |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 6 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 6 KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 250V | |||||||||||
MPPT Voltage Range | 130 –200V | |||||||||||
Minimum PV Voltage | 130V | |||||||||||
Max I/P Amps per channel | 62A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 96 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 4800WP | |||||||||||
Output AMP | 21 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 94% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
Modes Available | 3:Hybrid,Grid Export ,Stand Alone |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters | Solar GRP
PV Vol,Curr PV Power PV Energy |
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 8 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 8 KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 300V | |||||||||||
MPPT Voltage Range | 165–250V | |||||||||||
Minimum PV Voltage | 165V | |||||||||||
Max I/P Amps per channel | 66A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 120 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 800WP | |||||||||||
Output AMP | 3.5 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 75% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
Modes Available | 3:Hybrid,Grid Export ,Stand Alone |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters | Batt GRP
Voltage Status Current CH Current DISC |
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 10 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 10 KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 300V | |||||||||||
MPPT Voltage Range | 165–250V | |||||||||||
Minimum PV Voltage | 165V | |||||||||||
Max I/P Amps per channel | 83A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 120 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 800WP | |||||||||||
Output AMP | 35 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 75% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters | Dash board
Input KW Output KW Solar KW |
Modes Available | 3:Hybrid,Grid Export ,Stand Alone |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |
Grid Voltage Sync Range | 170V to 260V (±5V) |
Grid Frequency Sync Range | 50Hz ± 6% |
Charger Peak Efficiency | Higher than 90% |
Max Grid Import Power Capacity | Double of Inveter capacity dependent on battery charging current |
Max Batt Amp (Charging) | 5A to 20A selectable |
Self Consumption | Lower than 4% |
Recommended DG/GRID Capacity | Double of Inverter Capacity |
Charge Controller Type | MPPT | |||||||||||
Charger Topology | BUCK | |||||||||||
MAX PV Connection Capacity | 12.5 KWP | |||||||||||
No of MPPT Channels | 1 | |||||||||||
Per Channel PV Capacity (Nominal/ Peak) | 12.5 KWP | |||||||||||
Max. Open Circuit PV Volts (Voc) | 300V | |||||||||||
MPPT Voltage Range | 165–250V | |||||||||||
Minimum PV Voltage | 165V | |||||||||||
Max I/P Amps per channel | 104A | |||||||||||
Max Battery Amps during PV charging | Full Capacity in Boost Mode / Current Control in Float Mode as per Battery AH | |||||||||||
Battery type Supported | LMLA, VRLA, SMF, Ni-Cd: Charging Profile can be configured as per the battery requirement | |||||||||||
Peak Charging Efficiency | Higher than 94% Upto 98% |
Nominal Battery Voltage VDC | 120 | |||||||||||
No of Phases/Connection Type | 1Ph , 3 Wire- LNE | |||||||||||
Nominal Output Voltage | 230V AC ±2% | |||||||||||
Output Frequency | 50Hz ± 0.5% | |||||||||||
Continues Output Power | 800WP | |||||||||||
Output AMP | 3.5 | |||||||||||
Voltage Regulation(Stand Alone) | ±2% | |||||||||||
Frequency Regulation(Stand Alone) | ±0.5Hz | |||||||||||
THD | THD less than 4% | |||||||||||
OUTPUT Waveform | Pure Sine Wave | |||||||||||
Galvanic Isolation | In built Isolation Transformer at Inverter Output | |||||||||||
Output Power Factor | 0.8lagging | |||||||||||
Peak Efficiency (Full Load) | Higher than 75% | |||||||||||
Overload capacity | 125% FOR 60 SEC, 150% FOR 5 SEC / Can be customized | |||||||||||
DG Compatibility | Available | |||||||||||
Auto Bypass feature | Available | |||||||||||
Grid Export Mode | Available, Enable/Disable Options available | |||||||||||
Anti Islanding Function | Available, In Compliance with IEC 62116 | |||||||||||
Compatible IEC standards | IEC -61683:1999- As per MNRE Requirement |
LED | Grid On, PV On, Grid Charger On,, Load On Grid, Load On Battery , Fault |
LCD Display Parameters | Faults
Recent 6 fault since last reset |
Modes Available | 5: SBG, SGB, GSB, GFM, INV |
Battery Buffer Setting | Selectable from 25%,50%,75% |
MPPT Modes | 2 |